Product Name:Syringe pump A110
Item No.:A110
Description

Basic Parameter:
  1)- Dimensions(mm): 320(L)×145(W)×120(H)
  2)- Weight: about 3Kg
  3)- Power supply:AC90-242V 47-63HZ
  4)- Built-in batteries:DC 12V 1300mAh
  5)- Battery Model: JP-HSE-1.3-12V 
  6)- Battery Continuous Use Time:Above 6hrs
  7)- Power consumption:≤18VA
  8)- Infusion Flow Selection:0.1ml/h~599.9ml/h, original value is 0.1ml/h
  9)- Infusion Range:0.1ml~999.9ml, original value is 0.1ml
  10)- Flow Rate Precision:±3%(50ml/h≤ Flow Rate ≤599.9ml/h)
  11)- Occlusion Pressure:262.5~712.5mmHg±150(35~95kpa±20)
  12)- Use Environment:Temperature 5℃~43℃
  13)- Relative Humidity ≤90%RH (Under without condensation status)
  14)- Atmospheric Pressure 860hPa~1060hPa
  15)- Storage Environment:Temperature -40℃~+55℃
  16)- Relative Humidity ≤95%RH (Under without condensation status)
  17)- Atmospheric Pressure 860hPa~1060hPa
  18)- Waterproof Level: IPX1 (drip-proof)
  19)- Electric Shock Protection: Class I, Type BF
  20)- Alarm: self-test, occlusion, nearly finish, finish, low battery, battery exhausted, standby (no operation), move (including syringe drop, wrong fastening of syringe, shift of syringe)

* Basic Function: Automatically detect syringe type, indicate total infusion volume, indicate flow rate, indicate power supply, standby automatic alarm and KVO functions

* Special Functions:
  21)- Keep-Vein-Open (KVO): After finishing predetermined infusion volume, to prevent the formation of thrombus, continue infusion with preset minimum rate (0.1 ml/h).
  22)- Power Supply Switching Function: When the AC power supply is off, it will automatically switch to built-in battery power supply and prompt at the same time. When AC is switched on, it is automatically converted back to AC supply.
  23)- Repeat Alarm Function:  After the operator presses the “SILENCE” key, if the reason causing the alarm has be untreated for 2 minutes, the alarm will sound again to alert the operator to solve the problem.
  24)- Battery Protection Alarm:   In order to protect the battery and ensure infusion safety, there are different levels of acousto-optic prompts when the electric quantity of the battery is changing from close to depletion to almost depleted.
* MOQ: 12 pcs
* HS code: 9018909010
* Packing: 1 pc/carton, carton size:360x215x235mm, carton G.w./N.w.:3.9/3 kgs.